How long should you keep kitchen extract cleaning records?

The fire risk assessment asks for them. The insurer asks for them. The law never says for how long.

A plain answer for kitchen extract cleaning firms and the kitchens they clean for: what the law sets, what limitation periods mean for a report, and what insurers and fire officers ask to see.

Edward Bristow26 November 20264 min read

No UK fire safety law sets a retention period for kitchen extract cleaning records. The Regulatory Reform (Fire Safety) Order 2005 asks the responsible person to keep equipment "subject to a suitable system of maintenance" (Article 17) and to record the fire risk assessment (Article 9). Neither names a number of years.

So the real answer comes from three other places: how long someone can bring a claim, what your insurer will ask to see, and what a fire officer looks for after a fire.

Claims run for six years - sometimes fifteen

In England and Wales, a claim in contract or in negligence normally has to start within six years (Limitation Act 1980, sections 2 and 5). Work done under a deed runs for twelve (section 8). Where damage stays hidden, a negligence claim can start up to three years from when it is discovered, with a long stop of fifteen years from the work (section 14A and 14B). Scotland and Northern Ireland have their own rules.

A duct fire five years after a clean is well inside those windows. The post-clean report is the cleaner's evidence and the operator's.

Insurers want the history, not just the last clean

Aviva's published standard for commercial kitchen extract systems says formal records of inspections and cleaning schedules "should be maintained", and that reports should be compared with previous reports (Aviva Loss Prevention Standard, v1.4). You cannot compare against a report you threw away. Zurich's kitchen fire guidance makes the same point from the client side: get the documentation from your duct cleaning contractor (Zurich Resilience Solutions).

One Financial Ombudsman decision shows the cost. A takeaway's fire claim was declined under a cleaning condition; the paperwork that would have shown the cleans was lost in the fire, and the ombudsman found the insurer acted fairly (FOS DRN-5463547). Records kept only on paper in the kitchen burn with the kitchen.

Fire officers ask for them after a fire

London Fire Brigade's guidance note GN86 says auditing officers "will ask to see post-clean verification of cleanliness records", and after a fire they check whether areas listed as not cleaned were dealt with (LFB GN86, rev 3). The government's guide for small premises says a record of testing and maintenance "should be kept in the form of a logbook or an electronic record" (gov.uk).

A sensible rule

  • Keep every post-clean report and certificate for at least six years after the clean - longer if the work was done under a deed, or if your insurer or contract asks.
  • Keep them off site. A copy that lives only in the kitchen is no use after a fire.
  • Keep the areas not cleaned and the reasons. That is the line a fire officer and an insurer read first.
  • Invoices are separate. A limited company keeps accounting records for six years from the end of the financial year (gov.uk).

How SMART Reports keeps them

In SMART Reports the locked report and certificate are stored exactly as they were emailed. A correction is re-issued as Rev B and the original is kept. Areas not done and remedials are recorded on the job. Each firm has its own private database, never shared with another firm, and a whole-firm export is there at any time. More in our TR19 Grease report software guide and what your insurer will look for in a kitchen extract record.

This is general information, not legal advice. Check your insurance policy and contracts for any longer period they set.

Sources

  • Regulatory Reform (Fire Safety) Order 2005, Articles 9 and 17; Limitation Act 1980, sections 2, 5, 8, 14A, 14B - legislation.gov.uk, read 7 November 2026
  • Aviva Loss Prevention Standard, commercial kitchens - extract systems and cooking ranges, v1.4 (October 2024); Zurich Resilience Solutions, Fire safety in commercial kitchens (2023) - read 7 November 2026
  • Financial Ombudsman Service decision DRN-5463547 (2025); LFB Guidance Note 86, rev 3 (May 2022); gov.uk small premises fire safety guide and company records guidance - read 7 November 2026