Skip to content
SMART Solutions
LEV thorough examination and test

HSG258 explained: what HSE’s LEV guidance covers, chapter by chapter

One book covers LEV from first specification to the yearly test.

HSG258 is the Health and Safety Executive’s guide to local exhaust ventilation (LEV). Its full title is “Controlling airborne contaminants at work”. The third edition came out in 2017 and is free to download from HSE.

Edward Bristow19 November 20263 min read

What HSG258 is

HSG258 explains how to decide on, design, commission and test LEV, so that dust, fume, mist, vapour and gas are taken away before people breathe them in. It is written for employers who use LEV and for the firms that supply it.

Examiners use it as the reference for a thorough examination and test. Duty holders meet it when a report or a quotation names it.

Is HSG258 the law?

No. It is guidance. The legal duty sits in the Control of Substances Hazardous to Health Regulations 2002 (COSHH), mainly regulations 7 to 9.

HSE says that following the guidance is not compulsory unless it states otherwise, and that you are free to take other action. It also says that following it will normally be enough to meet the law, and that inspectors may refer to it.

What is in it, chapter by chapter

  1. About this book. Who it is for and how to use it.
  2. Introduction to LEV, roles and responsibilities. What LEV is, and what employers, suppliers and examiners each answer for.
  3. Properties of airborne contaminants. How dust, fume, mist, vapour and gas behave in air.
  4. Processes and sources. Where the contaminant cloud comes from and how it moves.
  5. Preparing a specification. What an employer should ask a supplier for.
  6. Hood design and application. The three kinds of hood: enclosing, receiving and capturing.
  7. Designing the rest of the system. Ducts, air movers, air cleaners and discharge.
  8. Installing and commissioning. Proving the system does what was specified.
  9. User manual and logbook. The paperwork that stays with the system.
  10. Thorough examination and test. The periodic check that the system still performs.

Two appendices follow: the legal requirements, and how to select a control benchmark and control requirement.

The chapters examiners use most

Chapter 10 is the one behind every report. It sets out what a thorough examination and test should look at and what the record should hold. Our guide to what an LEV report should show walks through that in plain words.

Chapter 8 matters just as much. The commissioning figures are the benchmark that later tests are judged against. Where no commissioning record exists, the first thorough examination often has to establish one.

Chapter 6 gives the hood names used on reports. Calling a hood enclosing, receiving or capturing tells the reader how it is meant to work and what to measure.

The user manual and logbook

HSG258 expects a supplier to hand over a user manual: how to use, check, maintain and test the system, with its performance benchmarks. It expects a logbook to record the routine checks, maintenance and parts replaced.

An examiner who is handed neither should say so in the report. It is one of the most common gaps on site.

How often, and how long to keep records

The interval comes from COSHH, not from HSG258: at least every 14 months for most systems, and 1 or 6 months for four named processes. See how often LEV should be tested. Records are kept for at least five years.

Where to get it

HSE publishes HSG258 as a free download and as a printed book. HSE also publishes two short companions: INDG408, a simple guide to buying and using LEV, and INDG409, a pocket guide for workers.

How LEV TExT fits in

With LEV TExT the examiner records each system, hood and reading once on the phone, and the office issues the PDF. £90 a month, every examiner and office user included.

LEV TExT by SMART Reports records LEV thorough examination and test reports on the examiner's phone. The examiner records each LEV system and its hoods or capture points, readings at each test point, photos, and the condition of hoods, ducting, filters and fan. Defects are recorded with the action needed, against the hood or part. The report is laid out in the HSG258 order and carries the date the next examination is due, which stays on the record for planning.

The office books on a laptop and the examiner works on the phone; both see the same job, and the office can open the draft PDF before it is issued. Only staff the firm holds an examiner qualification for (P601 or P604) can be chosen to examine and issue a report. £90 a month, every examiner and office user included. No VAT charged.

This guide explains HSE's guidance in plain words. It is not legal advice and it does not replace reading HSG258 itself.

Sources

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top